DIRECT VENT FIREPLACE WARNING: This product must be installed by a licensed plumber or gas fitter when installed in the commonwealth of Massachuse
FIREPLACE DIMENSIONS LETTER KEY A B C D E F G H DESCRIPTION Height Width Back Width Depth Opening Width Glass Frame Height Stand-off Hei
Top of unit face to framing - 10” (254 mm) From unit left & right sides & back - 1/4” (6 mm) To flooring - 0” (0 mm) Unit top to ceiling -
(#DSL-770) - Millivolt Board Assembly with 18” Flexible Gas Line attached (#700-203) - Manual Gas Shut-off Valve (#DSL-135) - Burner / Log Grate Ass
PREPARE THE FIREPLACE The top stand-off brackets and stand-off heat shield are attached to th
NAILING FLANGE ASSEMBLY & INSTALLATION When installed, nailing flanges provide the minimum 1/4” (6 mm) clearance from fireplace sides. 1. Remove
MINIMUM FINISHED OPENING DIMENSIONS FRAMING WALL ENCLOSURE ROUGH OPENING IMPORT
Determine the exact position of your fireplace, including hearth height, width, and depth, (if applicable). If possible, place fireplace in such a
IMPORTANT: KOZY HEAT WALL THIMBLE PASS-THRU (#800-WPT) MUST BE USED ON ALL HORIZONTAL VENT RUNS USING 5” x 8” VENTING. FOLLOW INSTRU
MANTEL REQUIREMENTS PAGE 15 HORIZONTAL VENT HEAT SHIELD 14-1/2” (368 mm) WARNING: NON-COMBUST
GLASS FRAME ASSEMBLY REMOVE GLASS FRAME ASSEMBLY A. Locate the spring-loaded handles securing glass frame assembly at the top & bottom of firebox
INSTALLATION OF THIS FAN SHOULD BE DONE ONLY BY A QUALIFIED INSTALLER IMPORTANT: If installing a fan, it is easier to complete before the millivolt bo
1. Insert fan through the lower grill opening on left side of gas valve. Align mounting slots in the fan bracket onto the mounting s
CAUTION: Installation of the gas line must only be done by a qualified person in accordance with local building codes, if any. If not, follow ANSI
CAUTION: DO NOT CONNECT HIGH VOLTAGE (115V) WIRE TO THE GAS VALVE! If desired, a thermostat (wireless style also available), wall switch, or
This fireplace is designed to be used with any of the following vent systems without the use of an additional adaptor. Refer to the vent systems manu
VENTING #800-WPT WALL PASS-THRU IMPORTANT: #800-WPT WALL PASS-THRU MUST BE USED O
6” (152 mm) VENT PIPE SECTION TERMINATION CAP VENTING NOTE: Horizontal sections
VENTING NOTE: Horizontal sections require 1/4” (6 mm) rise for every 12” (305 m
IMPORTANT: THE HORIZONTAL HEAT SHIELD INCLUDED WITH THIS FIREPLACE MUST BE INSTALLED WHEN USING A 90-DEGREE ELBOW DIRECTLY OFF THE TOP OF U
VENTING (Horizontal) 90° ELBOW NOTE: Horizontal sections require 1/4” (6 m
CONGRATULATIONS! We welcome you as a new owner of a Kozy Heat gas fireplace. Kozy Heat products are designed with superior components and material
For each additional 90° elbow used after the first elbow, 3 ft. (914 mm) must be subtracted from the maximum allowed venting. For each 45° elbow used
VENTING (Vertical) VERTICAL TERMINATIONS MINIMUM VERTICAL VENTING 5” x 8” MAXIM
VENTING (Vertical cont.) TERMINATION CAP VERTICAL TERMINATIONS MINIMUM VERTICAL V
VENTING (Vertical with Decreaser) For each additional elbow used after the first e
VENTING (Horizontal & Vertical Combination) CAUTION: This gas appliance must not be c
VENTING (Flexible (#800 Series) INSTALLATION OF #800 SERIES DIRECT VENT TERMINATIO
VENTING (Flexible #800 Series cont.) PAGE 33 B F D A TERMINATION BOX B SLOTS IN
BBLDENOTES WHERE INSTALLATION NOT ALLOWEDJKCGPHIODEANFM 1. Terminations against vinyl siding must use a vinyl siding protector. Follow instruction
Roof Pitch H (Min.) Ft. H (Min.) m Flat to 6/12 1.0 0.30 Over 6/12 to 7/12 1.25 0.38 Over 7/12 to 8/12 1.5 0.46 Over 8/12 to 9/12 2.0 0.61 O
LOG SET INSTALLATION ATTENTION: If converting to LP (propane) gas or installing the optional
LOG SET INSTALLATION STEP 2: #D2 & D3 Log Placement #D2 #D3 PAGE 37 PLACE THE FRONT L
LOG SET INSTALLATION #D4 #D5 STEP 3: #D4, #D5 & #D6 Log Placement #D6 PAGE 38 PLACE TH
LOG SET INSTALLATION STEP 4: COMPLETE LOG SET INSTALLATION PAGE 39 RANDOMLY PLACE „KLINKERS
MILLIVOLT BOARD REMOVAL 1. Turn gas control knob to the „OFF‟ position. 2. Shut off gas s
1. Place millivolt board in firebox, aligning the holes in the millivolt board with holes in the firebox bottom. MAKE SURE SEALING GASKET IS IN PLAC
UPPER LOUVER, HOOD & LOWER GRILL INSTALLATION A. Align hooks (A) in the upper louver to slots located in the fireplace face. Set down into pos
VALVE TERMINALS GAS CONTROL KNOB PIEZO IGNITOR HI /LO FLAME ADJUSTMENT KNOB ON/OFF ROCKER SWITCH ELECTRODE PILOT HOOD THERMOPILE THERMOCOUPLE PILOT S
FOR YOUR SAFETY - READ BEFORE LIGHTING WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT, CAUSING PROPERTY DAM
1. Set thermostat to the lowest setting, if installed. 2. Turn off all electrical power to the appliance. (Fan). 3. Open lower grill to access th
NOTE: This control valve has an interlock device. If pilot has been turned off, it cannot be relit until the thermocouple has cooled, (ap
TABLE OF CONTENTS PAGE 2 VENTING cont. Minimum Horizontal Corner Installation 24 Horizo
NOTE: The appliance and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that syste
FINALIZING THE INSTALLATION FLAME APPEARANCE: Flame appearance is affected by several factors including altitude, venting confi
FINALIZING THE INSTALLATION RESTRICTOR USAGE: Turn the fireplace on and allow to burn for 15 minutes. If flames indicate there
Annual examination of the venting system by a qualified agency is required. IF THE VENT-AIR INTAKE SYSTEM IS DISASSEMBLED FOR ANY REASON, RE-INSTALL
TROUBLESHOOTING NO SPARK FROM ELECTRODE TO PILOT WHEN PIEZO BUTTON IS TRIGGERED. A. Check
A. Gas control knob not turned to „ON‟. B. „ON‟/„OFF‟ switch not turned on. C. Remote, wall switch or remote control not turned „ON‟. D. Plugge
A. No LP (propane) in tank. ♦ Check tank and refill if necessary. B. Glass frame assembly not installed correctly. ♦ Refer to page 16 in th
Manufacturer Part # Cap Description KOZY HEAT 845 5x8 Flex Vent kit w/ cap SIMPSON 1283 5x8 Low Wind V. Cap 58DVA 5x8 High Wind V. Cap 58DVAHRC
Replacement parts are available through your local dealer. Contact them for availability and pricing. MILLIVOLT BOARD AND PARTS DSL-770 Dassel Mi
Installation and repair should be done only by a qualified service person. The appliance should be inspected by a qualified service person befo
PAGE 57
High efficiency High quality lifetime glass 23-3/4” x 30-1/16” (603 mm x 764 mm) Quick latch glass frame assembly Upper grill / hood & lowe
COMMONWEALTH OF MASSACHUSETTS REQUIREMENTS NOTE: The following requirements reference various Massachusetts and national
COMMONWEALTH OF MASSACHUSETTS REQUIREMENTS MANUFACTURER REQUIREMENTS - GAS EQUIPMENT VENTING SYSTEM PROVIDED When the manufact