DIRECT VENT FIREPLACE
WARNING: This product must be
installed by a licensed plumber or gas
fitter when installed in the
commonwealth of Massachusetts.
IMPORTANT: Installation of a CO
detector is required in the fireplace
room when installed in the
commonwealth of Massachusetts.
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or
any other appliance.
IF YOU SMELL GAS:
Do not light any appliance.
Do not touch any electrical switch: do not use any phone in your building.
Immediately call gas supplier from a neighbors phone. Follow the gas supplier instructions.
If you cannot reach your gas supplier, call the fire department.
Installation and service must be performed by a qualified installer, service agency or the gas
supplier.
WARNING: If the information in these instructions are not followed exactly, a fire or
explosion may result, causing property damage, personal injury or loss of life.
This appliance may be installed in an aftermarket permanently located, manufactured (mobile) home,
where not prohibited by local codes.
This appliance is only for use with the type(s) of gas indicated on
the rating plate. A conversion kit is supplied with the appliance.
www.kozyheat.com
INSTALLATION
AND
OPERATION MANUAL
Quality Fireplaces for Life
DO NOT
DISCARD
INSTALLER: LEAVE THIS MANUAL WITH THE APPLIANCE.
CONSUMER: RETAIN THIS MANUAL FOR FUTURE REFERENCE.
January - 2008
Vedere la pagina 0
1 2 3 4 5 6 ... 62 63

Sommario

Pagina 1 - OPERATION MANUAL

DIRECT VENT FIREPLACE WARNING: This product must be installed by a licensed plumber or gas fitter when installed in the commonwealth of Massachuse

Pagina 2

FIREPLACE DIMENSIONS LETTER KEY A B C D E F G H DESCRIPTION Height Width Back Width Depth Opening Width Glass Frame Height Stand-off Hei

Pagina 3

Top of unit face to framing - 10” (254 mm) From unit left & right sides & back - 1/4” (6 mm) To flooring - 0” (0 mm) Unit top to ceiling -

Pagina 4

(#DSL-770) - Millivolt Board Assembly with 18” Flexible Gas Line attached (#700-203) - Manual Gas Shut-off Valve (#DSL-135) - Burner / Log Grate Ass

Pagina 5

PREPARE THE FIREPLACE The top stand-off brackets and stand-off heat shield are attached to th

Pagina 6

NAILING FLANGE ASSEMBLY & INSTALLATION When installed, nailing flanges provide the minimum 1/4” (6 mm) clearance from fireplace sides. 1. Remove

Pagina 7 - SAFETY FEATURES

MINIMUM FINISHED OPENING DIMENSIONS FRAMING WALL ENCLOSURE ROUGH OPENING IMPORT

Pagina 8

Determine the exact position of your fireplace, including hearth height, width, and depth, (if applicable). If possible, place fireplace in such a

Pagina 9

IMPORTANT: KOZY HEAT WALL THIMBLE PASS-THRU (#800-WPT) MUST BE USED ON ALL HORIZONTAL VENT RUNS USING 5” x 8” VENTING. FOLLOW INSTRU

Pagina 10 - FIREPLACE DIMENSIONS

MANTEL REQUIREMENTS PAGE 15 HORIZONTAL VENT HEAT SHIELD 14-1/2” (368 mm) WARNING: NON-COMBUST

Pagina 11 - CLEARANCES

GLASS FRAME ASSEMBLY REMOVE GLASS FRAME ASSEMBLY A. Locate the spring-loaded handles securing glass frame assembly at the top & bottom of firebox

Pagina 13

INSTALLATION OF THIS FAN SHOULD BE DONE ONLY BY A QUALIFIED INSTALLER IMPORTANT: If installing a fan, it is easier to complete before the millivolt bo

Pagina 14

1. Insert fan through the lower grill opening on left side of gas valve. Align mounting slots in the fan bracket onto the mounting s

Pagina 15 - WALL ENCLOSURE ROUGH OPENING

CAUTION: Installation of the gas line must only be done by a qualified person in accordance with local building codes, if any. If not, follow ANSI

Pagina 16 - VERTICAL TERMINATIONS

CAUTION: DO NOT CONNECT HIGH VOLTAGE (115V) WIRE TO THE GAS VALVE! If desired, a thermostat (wireless style also available), wall switch, or

Pagina 17 - TYPICAL CORNER INSTALLATION

This fireplace is designed to be used with any of the following vent systems without the use of an additional adaptor. Refer to the vent systems manu

Pagina 18

VENTING #800-WPT WALL PASS-THRU IMPORTANT: #800-WPT WALL PASS-THRU MUST BE USED O

Pagina 19 - GLASS FRAME ASSEMBLY

6” (152 mm) VENT PIPE SECTION TERMINATION CAP VENTING NOTE: Horizontal sections

Pagina 20

VENTING NOTE: Horizontal sections require 1/4” (6 mm) rise for every 12” (305 m

Pagina 21

IMPORTANT: THE HORIZONTAL HEAT SHIELD INCLUDED WITH THIS FIREPLACE MUST BE INSTALLED WHEN USING A 90-DEGREE ELBOW DIRECTLY OFF THE TOP OF U

Pagina 22 - GAS CONVERSION

VENTING (Horizontal) 90° ELBOW NOTE: Horizontal sections require 1/4” (6 m

Pagina 23 - REMOTE CONTROL:

CONGRATULATIONS! We welcome you as a new owner of a Kozy Heat gas fireplace. Kozy Heat products are designed with superior components and material

Pagina 24

For each additional 90° elbow used after the first elbow, 3 ft. (914 mm) must be subtracted from the maximum allowed venting. For each 45° elbow used

Pagina 25 - #800-WPT WALL PASS-THRU

VENTING (Vertical) VERTICAL TERMINATIONS MINIMUM VERTICAL VENTING 5” x 8” MAXIM

Pagina 26

VENTING (Vertical cont.) TERMINATION CAP VERTICAL TERMINATIONS MINIMUM VERTICAL V

Pagina 27 - Vent Heat Shield for clarity

VENTING (Vertical with Decreaser) For each additional elbow used after the first e

Pagina 28 - HORIZONTAL VENT HEAT SHIELD

VENTING (Horizontal & Vertical Combination) CAUTION: This gas appliance must not be c

Pagina 29

VENTING (Flexible (#800 Series) INSTALLATION OF #800 SERIES DIRECT VENT TERMINATIO

Pagina 30 - RESTRICTOR

VENTING (Flexible #800 Series cont.) PAGE 33 B F D A TERMINATION BOX B SLOTS IN

Pagina 31 - RESTRICTOR INSTALLATION

BBLDENOTES WHERE INSTALLATION NOT ALLOWEDJKCGPHIODEANFM 1. Terminations against vinyl siding must use a vinyl siding protector. Follow instruction

Pagina 32

Roof Pitch H (Min.) Ft. H (Min.) m Flat to 6/12 1.0 0.30 Over 6/12 to 7/12 1.25 0.38 Over 7/12 to 8/12 1.5 0.46 Over 8/12 to 9/12 2.0 0.61 O

Pagina 33

LOG SET INSTALLATION ATTENTION: If converting to LP (propane) gas or installing the optional

Pagina 35

LOG SET INSTALLATION STEP 2: #D2 & D3 Log Placement #D2 #D3 PAGE 37 PLACE THE FRONT L

Pagina 36

LOG SET INSTALLATION #D4 #D5 STEP 3: #D4, #D5 & #D6 Log Placement #D6 PAGE 38 PLACE TH

Pagina 37 - LOCATION CLEARANCES

LOG SET INSTALLATION STEP 4: COMPLETE LOG SET INSTALLATION PAGE 39 RANDOMLY PLACE „KLINKERS

Pagina 38 - VENT TERMINATION CLEARANCES

MILLIVOLT BOARD REMOVAL 1. Turn gas control knob to the „OFF‟ position. 2. Shut off gas s

Pagina 39 - STEP 1: #D1 Log Placement

1. Place millivolt board in firebox, aligning the holes in the millivolt board with holes in the firebox bottom. MAKE SURE SEALING GASKET IS IN PLAC

Pagina 40 - PAGE 37

UPPER LOUVER, HOOD & LOWER GRILL INSTALLATION A. Align hooks (A) in the upper louver to slots located in the fireplace face. Set down into pos

Pagina 41

VALVE TERMINALS GAS CONTROL KNOB PIEZO IGNITOR HI /LO FLAME ADJUSTMENT KNOB ON/OFF ROCKER SWITCH ELECTRODE PILOT HOOD THERMOPILE THERMOCOUPLE PILOT S

Pagina 42

FOR YOUR SAFETY - READ BEFORE LIGHTING WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT, CAUSING PROPERTY DAM

Pagina 43 - BURNER

1. Set thermostat to the lowest setting, if installed. 2. Turn off all electrical power to the appliance. (Fan). 3. Open lower grill to access th

Pagina 44 - Venturi opening

NOTE: This control valve has an interlock device. If pilot has been turned off, it cannot be relit until the thermocouple has cooled, (ap

Pagina 45 - Thread screws into nuts on

TABLE OF CONTENTS PAGE 2 VENTING cont. Minimum Horizontal Corner Installation 24 Horizo

Pagina 46

NOTE: The appliance and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that syste

Pagina 47

FINALIZING THE INSTALLATION FLAME APPEARANCE: Flame appearance is affected by several factors including altitude, venting confi

Pagina 48 - LIGHTING

FINALIZING THE INSTALLATION RESTRICTOR USAGE: Turn the fireplace on and allow to burn for 15 minutes. If flames indicate there

Pagina 49 - TURN PILOT OFF

Annual examination of the venting system by a qualified agency is required. IF THE VENT-AIR INTAKE SYSTEM IS DISASSEMBLED FOR ANY REASON, RE-INSTALL

Pagina 50 - INLET PRESSURE TEST:

TROUBLESHOOTING NO SPARK FROM ELECTRODE TO PILOT WHEN PIEZO BUTTON IS TRIGGERED. A. Check

Pagina 51 - TO ADJUST VENTURI:

A. Gas control knob not turned to „ON‟. B. „ON‟/„OFF‟ switch not turned on. C. Remote, wall switch or remote control not turned „ON‟. D. Plugge

Pagina 52 - RESTRICTOR USAGE:

A. No LP (propane) in tank. ♦ Check tank and refill if necessary. B. Glass frame assembly not installed correctly. ♦ Refer to page 16 in th

Pagina 53

Manufacturer Part # Cap Description KOZY HEAT 845 5x8 Flex Vent kit w/ cap SIMPSON 1283 5x8 Low Wind V. Cap 58DVA 5x8 High Wind V. Cap 58DVAHRC

Pagina 54

Replacement parts are available through your local dealer. Contact them for availability and pricing. MILLIVOLT BOARD AND PARTS DSL-770 Dassel Mi

Pagina 56

Installation and repair should be done only by a qualified service person. The appliance should be inspected by a qualified service person befo

Pagina 59

PAGE 57

Pagina 61

High efficiency High quality lifetime glass 23-3/4” x 30-1/16” (603 mm x 764 mm) Quick latch glass frame assembly Upper grill / hood & lowe

Pagina 62 - PAGE 57

COMMONWEALTH OF MASSACHUSETTS REQUIREMENTS NOTE: The following requirements reference various Massachusetts and national

Pagina 63

COMMONWEALTH OF MASSACHUSETTS REQUIREMENTS MANUFACTURER REQUIREMENTS - GAS EQUIPMENT VENTING SYSTEM PROVIDED When the manufact